265 research outputs found

    Imaging of Hepatocellular Carcinoma by Computed Tomography and Magnetic Resonance Imaging: State of the Art

    Get PDF
    Hepatocellular carcinoma (HCC) is a very frequent tumor worldwide. Its incidence is linked to the distribution of liver cirrhosis and viral hepatitis, which are the main risk factors for the development of HCC. For the evaluation of the cirrhotic liver and for the diagnosis of HCC, multidetector computed tomography (MDCT) proved to be a robust and reliable tool. In MDCT the diagnosis of HCC can be made based on neovascularization with increased arterial and decreased portal venous supply. With modern magnetic resonance imaging (MRI), spatial resolution and robustness increased dramatically. Beside the evaluation of neovascularization by means of gadolinium-enhanced early dynamic MRI, the main advantages of MRI are additional information on tissue composition and liver-specific function. With diffusion-weighted imaging or plain T(1)- and T(2)-weighted sequences, different tissue elements like fat, hemorrhage, glycogen, edema and cellular density can be evaluated. Liver-specific contrast agents give insight into the Kupffer cell density or the hepatocellular function. The integration of all these parts into the MR examination allows for a very high detection rate for overt HCC nowadays, although very small HCCs are still a challenge. Moreover, insight into the different stages of hepatocarcinogenesis can be possible with MRI. Despite its limited availability in some countries, it has to be rendered to be the modality of choice for the distinct evaluation of the cirrhotic liver. Copyright (C) 2009 S. Karger AG, Base

    Improved quality of life in patients with refractory or recidivant ascites after insertion of transjugular intrahepatic portosystemic shunts

    Get PDF
    Background. We have recently shown that the transjugular intrahepatic portosystemic shunt (TIPS) is more effective than paracentesis in the treatment of cirrhotic patients with severe ascites and can prolong survival in selected patients. Although an improved quality of life (QOL) has been suggested in these patients after the TIPS procedure, so far there are no data available to substantiate this assumption. Therefore, the aim of this study was to determine the effect of TIPS on the QOL in cirrhotic patients with refractory or recidivant ascites. Methods: 21 cirrhotic patients who underwent TIPS for refractory or recidivant ascites were investigated. All patients were pretreated with repeated paracentesis for at least 1 year. Before the procedure and at 3 and 6 months during follow-up, the patients themselves rated QOL, fatigue and physical performance on a visual analogue scale (range 0-100). Furthermore, QOL was determined by the QOL index (range 0-10) according to Spitzer. Results: Patients' rating of the QOL on the visual analogue scale significantly increased from 35 +/- 25 (baseline) to 64 +/- 28 (3 months), and 66 +/- 24 (6 months; p = 0.02). Similarly, the QOL index significantly increased from 6.9 +/- 2.0 (baseline) to 8.3 +/- 2.1 (3 months), and 8.6 +/- 1.7 (6 months; p < 0.001). The increase of QOL was more pronounced in patients with complete response to TIPS. Conclusions: We demonstrate that TIPS for refractory or recidivant ascites improves the QOL in patients with cirrhosis. Our data indicates that this improvement is dependent on the response to therapy. Copyright (C) 2002 S. Karger AG, Basel

    Model-free functional MRI analysis based on unsupervised clustering

    Get PDF
    AbstractConventional model-based or statistical analysis methods for functional MRI (fMRI) are easy to implement, and are effective in analyzing data with simple paradigms. However, they are not applicable in situations in which patterns of neural response are complicated and when fMRI response is unknown. In this paper the “neural gas” network is adapted and rigourosly studied for analyzing fMRI data. The algorithm supports spatial connectivity aiding in the identification of activation sites in functional brain imaging. A comparison of this new method with Kohonen’s self-organizing map and with a fuzzy clustering scheme based on deterministic annealing is done in a systematic fMRI study showing comparative quantitative evaluations. The most important findings in this paper are: (1) both “neural gas” and the fuzzy clustering technique outperform Kohonen’s map in terms of identifying signal components with high correlation to the fMRI stimulus, (2) the “neural gas” outperforms the two other methods with respect to the quantization error, and (3) Kohonen’s map outperforms the two other methods in terms of computational expense. The applicability of the new algorithm is demonstrated on experimental data

    Women in radiology: gender diversity is not a metric-it is a tool for excellence.

    Get PDF
    Women in Focus: Be Inspired was a unique programme held at the 2019 European Congress of Radiology that was structured to address a range of topics related to gender and healthcare, including leadership, mentoring and the generational progression of women in medicine. In most countries, women constitute substantially fewer than half of radiologists in academia or private practice despite frequently accounting for at least half of medical school enrolees. Furthermore, the proportion of women decreases at higher academic ranks and levels of leadership, a phenomenon which has been referred to as a "leaky pipeline". Gender diversity in the radiologic workplace, including in academic and leadership positions, is important for the present and future success of the field. It is a tool for excellence that helps to optimize patient care and research; moreover, it is essential to overcome the current shortage of radiologists. This article reviews the current state of gender diversity in academic and leadership positions in radiology internationally and explores a wide range of potential reasons for gender disparities, including the lack of role models and mentorship, unconscious bias and generational changes in attitudes about the desirability of leadership positions. Strategies for both individuals and institutions to proactively increase the representation of women in academic and leadership positions are suggested. KEY POINTS: • Gender-diverse teams perform better. Thus, gender diversity throughout the radiologic workplace, including in leadership positions, is important for the current and future success of the field. • Though women now make up roughly half of medical students, they remain underrepresented among radiology trainees, faculty and leaders. • Factors leading to the gender gap in academia and leadership positions in Radiology include a lack of role models and mentors, unconscious biases, other societal barriers and generational changes

    Monitoring Early Response to Anti-Angiogenic Therapy: Diffusion-Weighted Magnetic Resonance Imaging and Volume Measurements in Colon Carcinoma Xenografts

    Get PDF
    Objectives: To evaluate the use of diffusion-weighted MRI (DW-MRI) and volume measurements for early monitoring of antiangiogenic therapy in an experimental tumor model. Materials and Methods: 23 athymic nude rats, bearing human colon carcinoma xenografts (HT-29) were examined before and after 6 days of treatment with regorafenib (n=12) or placebo (n=11) in a clinical 3-Tesla MRI. For DW-MRI, a single-shot EPI sequence with 9 b-values (10-800 s/mm(2)) was used. The apparent diffusion coefficient (ADC) was calculated voxelwise and its median value over a region of interest, covering the entire tumor, was defined as the tumor ADC. Tumor volume was determined using T2-weighted images. ADC and volume changes between first and second measurement were evaluated as classifiers by a receiver-operator-characteristic (ROC) analysis individually and combined using Fisher's linear discriminant analysis (FLDA). Results: All ADCs and volumes are stated as median +/- standard deviation. Tumor ADC increased significantly in the therapy group (0.76 +/- 0.09x10(-3) mm(2)/s to 0.90 +/- 0.12x10(-3) mm(2)/s;p<0.001), with significantly higher changes of tumor ADC than in the control group (0.10 +/- 0.11x10(-3) mm(2)/s vs. 0.03 +/- 0.09x10(-3) mm(2)/s;p = 0.027). Tumor volume increased significantly in both groups (therapy: 347.8 +/- 449.1 to 405.3 +/- 823.6 mm(3);p = 0.034;control: 219.7 +/- 79.5 to 443.7 +/- 141.5 mm(3);p<0.001), however, the therapy group showed significantly reduced tumor growth (33.30 +/- 47.30% vs. 96.43 +/- 31.66%;p<0.001). Area under the curve and accuracy of the ADC-based ROC analysis were 0.773 and 78.3%;and for the volume change 0.886 and 82.6%. The FLDA approach yielded an AUC of 0.985 and an accuracy of 95.7%. Conclusions: Regorafenib therapy significantly increased tumor ADC after 6 days of treatment and also significantly reduced tumor growth. However, ROC analyses using each parameter individually revealed a lack of accuracy in discriminating between therapy and control group. The combination of both parameters using FLDA substantially improved diagnostic accuracy, thus highlighting the potential of multi-parameter MRI as an imaging biomarker for non-invasive early tumor therapy monitoring

    Age-dependent differences in human brain activity using a face- and location-matching task: An fMRI study

    Get PDF
    Purpose: To evaluate the differences of cortical activation patterns in young and elderly healthy subjects for object and spatial visual processing using a face- and location-matching task. Materials and Methods: We performed a face- and a location-matching task in 15 young (mean age: 28 +/- 9 years) and 19 elderly (mean age: 71 +/- 6 years) subjects. Each experiment consisted of 7 blocks alternating between activation and control condition. For face matching, the subjects had to indicate whether two displayed faces were identical or different. For location matching, the subjects had to press a button whenever two objects had an identical position. For control condition, we used a perception task with abstract images. Functional imaging was performed on a 1.5-tesla scanner using an EPI sequence. Results: In the face-matching task, the young subjects showed bilateral (right 1 left) activation in the occipito-temporal pathway (occipital gyrus, inferior and middle temporal gyrus). Predominantly right hemispheric activations were found in the fusiform gyrus, the right dorsolateral prefrontal cortex (inferior and middle frontal gyrus) and the superior parietal gyrus. In the elderly subjects, the activated areas in the right fronto-lateral cortex increased. An additional activated area could be found in the medial frontal gyrus (right > left). In the location-matching task, young subjects presented increased bilateral (right > left) activation in the superior parietal lobe and precuneus compared with face matching. The activations in the occipito-temporal pathway, in the right fronto-lateral cortex and the fusiform gyrus were similar to the activations found in the face-matching task. In the elderly subjects, we detected similar activation patterns compared to the young subjects with additional activations in the medial frontal gyrus. Conclusion: Activation patterns for object-based and spatial visual processing were established in the young and elderly healthy subjects. Differences between the elderly and young subjects could be evaluated, especially by using a face-matching task. Copyright (c) 2007 S. Karger AG, Basel

    Metabolic syndrome predicts vascular changes in whole body magnetic resonance imaging in patients with long standing diabetes mellitus

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Although diabetic patients have an increased rate of cardio-vascular events, there is considerable heterogeneity with respect to cardiovascular risk, requiring new approaches to individual cardiovascular risk factor assessment. In this study we used whole body-MR-angiography (WB-MRA) to assess the degree of atherosclerosis in patients with long-standing diabetes and to determine the association between metabolic syndrome (MetS) and atherosclerotic burden.</p> <p>Methods</p> <p>Long standing (≥10 years) type 1 and type 2 diabetic patients (n = 59; 31 males; 63.3 ± 1.7 years) were examined by WB-MRA. Based on the findings in each vessel, we developed an overall score representing the patient's vascular atherosclerotic burden (MRI-score). The score's association with components of the MetS was assessed.</p> <p>Results</p> <p>The median MRI-score was 1.18 [range: 1.00-2.41] and MetS was present in 58% of the cohort (type 2 diabetics: 73%; type 1 diabetics: 26%). Age (p = 0.0002), HDL-cholesterol (p = 0.016), hypertension (p = 0.0008), nephropathy (p = 0.0093), CHD (p = 0.001) and MetS (p = 0.0011) were significantly associated with the score. Adjusted for age and sex, the score was significantly (p = 0.02) higher in diabetics with MetS (1.450 [1.328-1.572]) compared to those without MetS (1.108 [0.966-1.50]). The number of MetS components was associated with a linear increase in the MRI-score (increase in score: 0.09/MetS component; r<sup>2 </sup>= 0.24, p = 0.038). Finally, using an established risk algorithm, we found a significant association between MRI-score and 10-year risk for CHD, fatal CHD and stroke.</p> <p>Conclusion</p> <p>In this high-risk diabetic population, WB-MRA revealed large heterogeneity in the degree of systemic atherosclerosis. Presence and number of traits of the MetS are associated with the extent of atherosclerotic burden. These results support the perspective that diabetic patients are a heterogeneous population with increased but varying prevalence of atherosclerosis and risk.</p

    Comparative study of the corrosion behavior of peripheral stents in an accelerated corrosion model: experimental in vitro study of 28 metallic vascular endoprostheses

    Get PDF
    PURPOSEClinical cases of stent-fractures show that corrosion behavior might play a role in these fractures. Implanted in vivo, especially in combination with other implanted foreign materials, these metallic products are exposed to special conditions, which can cause a process of corrosion. Here, we aimed to test the corrosion potential of stents made of different materials in an in vitro setting.METHODSA total of 28 peripheral stents of different materials (nitinol, cobalt-chromium-nickel, tantalum, V4A) and surface treatments (electropolish, mechanical polish, no polish) were tested in vitro. Corrosion was accelerated by applying a constant voltage of 3.5 V and amperage of 1.16 mA in 0.9% NaCl.RESULTSNitinol stents showed the lowest susceptibility to corrosion and the longest period without damage. The Memotherm II® (BARD Angiomed®) was the only stent that showed neither macroscopic nor microscopic damages. The worst performing material was cobalt-chromium-nickel, which showed corrosion damages about ten times earlier compared to nitinol. Considering the reasons for termination of the test, nitinol stents primarily showed length deficits, while V4A and tantalum stents showed fractures. Cobalt-chromium-nickel stents had multiple fractures or a complete lysis in equal proportions. When placed in direct contact, nitinol stents showed best corrosion resistance, regardless of what material they were combined with. In terms of polishing treatments, electropolished stents performed the best, mechanical-polished stents and those without polishing treatment followed.CONCLUSIONThe analysis of corrosion behavior may be useful to select the right stent fulfilling the individual needs of the patient within a large number of different stents

    Submillisievert Computed Tomography of the Chest Using Model-Based Iterative Algorithm: Optimization of Tube Voltage With Regard to Patient Size

    Get PDF
    Objective: The aim of this study was to define optimal tube potential for soft tissue and vessel visualization in dose-reduced chest CT protocols using model-based iterative algorithm in average and overweight patients. Methods: Thirty-six patients receiving chest CTaccording to 3 protocols (120 kVp/noise index [NI], 60;100 kVp/NI, 65;80 kVp/NI, 70) were included in this prospective study, approved by the ethics committee. Patients' physical parameters and dose descriptors were recorded. Images were reconstructed with model-based algorithm. Two radiologists evaluated image quality and lesion conspicuity;the protocols were intraindividually compared with preceding control CT reconstructed with statistical algorithm (120 kVp/NI, 20). Mean and standard deviation of attenuation of the muscle and fat tissues and signal-to-noise ratio of the aorta were measured. Results: Diagnostic images (lesion conspicuity, 95%-100%) were acquired in average and overweight patients at 1.34, 1.02, and 1.08 mGy and at 3.41, 3.20, and 2.88 mGy at 120, 100, and 80 kVp, respectively. Data are given as CT dose index volume values. Conclusions: Model-based algorithm allows for submillisievert chest CT in average patients;the use of 100 kVp is recommended
    corecore